Home : Products : Hach WIMS : Interfaces : Hach WIMS Direct Server-Side Interface to Custom Q13156 LIMS : Documentation : Topics specific to the operation of this interface : Configuration - Source Configuration Q13156
Q13163 - INFO: Configuration - Source Configuration Q13156

This is the source configuration screen for the Hach WIMS Direct Server-Side Interface to Custom Q13156 LIMS.

In order to configure source connection from the interface, click Configuration and select Source Configuration.

The next screen will display parameters on two tabs. The first is Database Connection:

  • Configuration Template - one possible template is included in Custom Q13156 LIMS interface; for MS Access. These will fill in the most common values for the database connection.
  • DBMS Type - Select the source LIMS database system type from one of these:
    • Microsoft Access
  • OLE DB Provider - this will be filled in with Configuration Template and DBMS Type, and can be modified if needed.
  • Data Source - this field specifies, in loose terms, the "Database/Datasource server name" where your source LIMS database is stored. This field is only used to test the connection.
  • Username - The username you want to use to connect to the database. This user should have permission to access the database and tables that contain data.
  • Password - The password associated with the Username and is used to connect to the database.
  • Advanced Configuration - these permit adjustment of the command and connection timeout.

    • Connection Timeout in Seconds - how many seconds the program should wait when establishing a connection.
    • Command Timeout in Seconds - specifies how many seconds the program should wait for a query to complete before aborting the operation.

The second tab is Advanced Settings:

  • LIMS Source Data Folders
    • Import Data From Folder - This is the folder and file mask (off to the right) to be used when importing data from source LIMS database. If the folder does not exist, it will prompt you to create it.
    • Archive Data To Folder - This is the folder where the source LIMS database files are moved to after being processed. If the folder does not exist, it will prompt you to create it.
  • Table field definitions - Used to identify the fields in the source databases so the interface knows which fields to use. 
    • LIMS Location - The field in the source EDD Table that identifies the Location.  Is typically the SampleLocation field.  This field is matched to the variable's LIMS Location field (set on the Variable's Interface Tab - see supported variable configurations)

    • LIMS Test - The field in the source EDD Table that idenifies the Test or Analyte.  Is typically the Analyte field.  This field is matched to the variable's LIMS Test field (set on the Variable's Interface Tab - see supported variable configurations)

    • LIMS Date - This is the date field used for the date and time stamp of the result, typically SampleDate field.  Results are stored in the WIMS database for this date. 

    • LIMS Result - This is the result field used to import the value, typically SampleResult field.  This field contains the entire result including data qualifiers (i.e. <2, ND, etc...). 

    • LIMS Qualifier - Field is not used in the import (qualifiers should be included in the LIMS Result field).  However it must be mapped.  Is typically Qualifiers field.

    • LIMS Units - This is the units field used in unit conversion if enabled, typically UnitOfSample field.

 

  • Ignore Case when matching between Source Identifiers and WIMS Variable Cross References - If Enabled, then both the source data identifiers and the Hach WIMS variable cross reference will be changed to upper case. If Disabled, then both the source data identifiers and the Hach WIMS variable cross reference are used as-is (case sensitive matching).

  • Import Invalid Results as Hach WIMS Result Comments - When importing a result if the result is not a valid value for WIMS, import the result as a result comment. For example, the Result in LIMS is NS which is not a value that can be entered into WIMS (i.e. NS is not a WIMS symbol) the NS is imported as a Result Comment and the value in WIMS is left blank. NOTE: Will overwrite any existing result comment.


 

Related Articles
No Related Articles Available.

Article Attachments
No Attachments Available.

Related External Links
No Related Links Available.
Help us improve this article...
What did you think of this article?

poor 
1
2
3
4
5
6
7
8
9
10

 excellent
Tell us why you rated the content this way. (optional)
 
Approved Comments...
No user comments available for this article.
Created on 8/30/2010 9:36 AM.
Last Modified on 10/18/2013 11:06 AM.
Last Modified by Scott Dorner.
Article has been viewed 3274 times.
Rated 0 out of 10 based on 0 votes.
Print Article
Email Article