Home : Products : Hach WIMS : Hach WIMS Client : Documentation : Main Menu : Modeling : Clarifier Analysis : Add New Flux Curve
Q11848 - INFO: Add New Flux Curve

 

Allows entry of solids settling data to create and save new flux plots.  These flux plots are then used with State Point Analysis in predicting clarifier performance.

USING:

Choose a date and enter pairs of Concentration/Settling Velocity Tests.  The Curve equation will automatically be calculated.  Click Save to add the curve to the list of availiable curves.

Settling Velocity (ft/hr) tests need to be run on several concentrations of MLSS.  The recommended concentrations are:

  • 50% aeration basin MLSS
  • 75% aeration basin MLSS
  • Actual aeration basin MLSS
  • 75% recycle concentration
  • Actual recycle concentration

 

BUTTONS:

Saves the current curve to the database for later use.

Closes the form.  Changes are not saved.

Related Articles
No Related Articles Available.

Article Attachments
No Attachments Available.

Related External Links
No Related Links Available.