With the release of WIMS Client 8.1.8 a database upgrade is required. The upgrade is automatically applied when logging into a Facility Database for the first time with the WIMS 8.1.8.
Tech Notes:
SQL Server Scripts:
ALTER TABLE LC_BATCHTEMPLATEQC ALTER COLUMN RECORDER NUMERIC NOT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCULATORTYPE [nvarchar](50) NULL DEFAULT (NULL)
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT1 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT2 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT3 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT4 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT5 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD CALCINPUT6 FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD INPUTRL FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD INPUTMDL FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD MDL FLOAT NULL
ALTER TABLE LC_SAMPLETEST ADD RL FLOAT NULL
ALTER TABLE LC_BATCH ADD CALCULATORTYPE [nvarchar](50) NULL DEFAULT (NULL)
ALTER TABLE LC_SAMPLETEST ALTER COLUMN BATCHQCFORMULA NVARCHAR(100)